System Installation
46 025-9035AA
Connecting the Digi One SP to the network
1. Remove the module from its packing and confirm that its DIP switch is set to EIA-
232 (see page 44).
2. Locate the MAC address printed on the bottom line of the factory label on Digi
One SP module. Write this number down because you will need it during the initial
setup. (It is labeled “MA: xxxx:xxxx”.)
3. Install the loopback device supplied with the unit on the serial port D-connector of
the Digi One SP.
4. Plug the power supply into the module and then into a wall socket. Do not expect
the power LED to come on right away.
5. Plug the Ethernet cable into the RJ-45 jack on the module and plug the other end of
the cable into any available port on the network. This must be the same network
that serves the PC you intend to use for configuring the module and in which the
module will be used. The port used does not need to be the port to which the
module will finally end up connected.
The Power and Link LEDs should both be on at this point.
Performing the initial configuration using the Digi software tool
1. Insert the CD-ROM into the disk drive and close the drive. If the top screen for the
utilities does not start automatically, use the RUN option on the START menu.
2. From the opening screen, select the Digi Device Setup Wizard. The opening screen
of the wizard will look like the following. Click Next.
3. Once the software has scanned the network available to it, it will display the IP and
MAC addresses of any Digi One units it finds. Select the MAC address for the unit
you are configuring and then click on Next.