Appendix A: TAP Protocol Summary
364 025-9035AA
Transferring Pages
Once initial logon successful:
This sequence is repeated for each alpha page to be sent.
M2x00 sends:
(Displayed) AED sends:
Notes
<STX><pager#><CR>
<message><CR>
<ETX><checksum><C
R>
Send message to pager#. Pager # is exact # in database.
Checksum is arithmetic sum of all preceding 7-bit chars in
the block; the 12 LSBs of this sum are grouped into 3 4-bit
nybbles, 30h added to each nybble to make 3 ASCII chars.
The ASCII characters will be from the set 0-9:;<=>? with
any other value being illegal. (See checksum example on
following page.) A block can be no longer than 256
characters starting with the <STX> through the final <CR>.
The handling of long messages that would exceed the block
size limit will be described below.
<ACK><CR>msg Page received OK. msg=* acknowledged *<LF><CR>
OR
<NAK><CR>msg Checksum error, retransmit requested. msg=* retransmit
*<LF><CR>
OR
<RS><CR>msg Invalid pager #, or too many (3) checksum retries. msg=*
transaction rejected *<LF><CR> In practice, the above
message is not seen. Instead, you will see one of these:
msg=Invalid pager number<CR><LF><CR>
msg=System error<CR><LF><CR>
msg=System busy<CR><LF><CR>
msg=Database error<CR><LF><CR>
msg=Message required - page cancelled<CR><LF><CR>
OR
<ESC><EOT>msg M2x00 disconnecting. msg=* bye *<LF><CR> The M2x00
will disconnect if the trunk or alpha input line has a timeout
programmed and there has been no input for the timeout
interval. This forced logout may also occur if too many (3 in
a row) <RS> events occur.