29
Installation Checklist
8. [_] Connect the transmitter equipment (or test/measurement equipment if the
transmitter cannot be connected at this time) to the station card(s) of the paging
terminal.
Connection the transmitter/test equipment to the station card(s) via the connectors
on the right side of the lower backplane (see Figure 3 or Figure 4). Refer to Radio
Connectors on page 98, for specific connection information.
An amplified speaker can be connected to the XMIT and GND outputs on the front
of the Station card for monitoring analog paging in absence of a transmitter.
9. [_] Install the office computer software; ZbaseW, ZlinkW, etc. Refer to Installing
the Office Software on page 55. (For more complete information on the ZbaseW
program, see the Series 2000 Operation and Programming manual, 025-9034-001.)
10. [_] If you have any trouble linking up to the paging terminal with ZlinkW, refer to
the Troubleshooting the Office Computer on page 186.
11. [_] To test operation of the paging terminal, it is necessary at this point to create a
“test” subscriber database. This database is created by using ZbaseW on your
office computer as described in Installing Office Software on page 57. (For
additional information on the ZbaseW program, see the Series 2000 Operation and
Programming manual, 025-9034-001.)
12. [_] Make several test pages and verify pagers activate and audio levels are correct.
Note that the telephone trunk circuitry contains AGC circuitry that boosts recorded
audio to its maximum. Therefore, do not use the FROM TEL adjustments for audio
level adjustment; instead, use the adjustments on the Station card per the next
subsection, Alignment Procedure on page 30.
If you experience difficulty getting the system to operate normally, refer to
Troubleshooting and Repair Procedures on page 179.
13. [_] Mount the paging terminal in its final location (see Figure 5).
a. For the Model 2200, remove the bottom cover (unscrew, slide toward you, and
tilt down). Then remove the hard disk card, and the circuit cards from slots 1,
2, 15, and 16 to gain access to the mounting holes on the back panel of the
paging terminal. Refer to Model 2200 Cabinet Mounting Information on page
36 for details.
b. For the Model 2100, attach the mounting brackets to the side panels with
hardware supplied. Attach the paging terminal to the wall with lag screws, or
to an equipment rack with supplied hardware. Refer to Model 2100 Cabinet
Mounting Information on page 36 for details.
14. [_] Make all permanent telephone line connections to the RJ2EX connectors on the
left side of the backplane and radio transmitter connections to the connectors on
the right side of the backplane. Refer to Figure 3 or Figure 4.
Note Only tone and voice can be monitored by this method, unless tone
remote control is used. Then digital can be heard as modem tones.